Switch language: English Switch language: Deutsch

Inverter - Accessories SMA

Accessories SMA


1 - 10 from 27 Results

SMA mounting plate for Sensor Box

30.94 €

SMA mounting plate for Sensor Box, for fixing the Box

for fixing the Sensor Box at the panel

Price incl. VAT plus delivery

Item number: S-05-00038
Delivery time:
by request

SMA Power Balancer-Connector-System PBL-SMC-10-NR

52.04 €

SMA Power Balancer for retrofitting, PBL-SMC-10-NR

Cable SMA for retrofitting single phase devices to install the Power Balancer (standard at: SMA SMC 9000/10000/11000TLRP)

Price incl. VAT plus delivery

Item number: S-04-000432
Delivery time:
by request

SMA Power Balancer Y-Connector Cable 10-PBL-YCABLE-10

66.44 €

SMA Power Balancer connection cable Y-shaped PBL-YCABLE-10

cable 2x2m Compatible with: SMC 9000/10000/11000TLRP for all other devices, the SMA Power Balancer connector system is used in addition (our Item. S 04-000432)

Price incl. VAT plus delivery

Item number: S-04-000431
Delivery time:
by request

SMA Sunny Beam antenna extender

66.64 €

SMA Sunny Beam antenna extender, 10 meters, improvement of the antenna alignment

With this external antenna kit you can improve the antenna direction if the location of the inverters and the Sunny Beam cannot be optimally chosen. So possibly a wall or ceiling can be bridged.

Price incl. VAT plus delivery

Item number: S-05-00030
Delivery time:
by request

SMA RS485-Interface 485PB-NR

85.98 €

SMA RS485-Interface, 485PB-NR, Piggy Back, is used to retrofit

SMA Interface for retrofitting, suitable for inverter: SMA SB 1200, 1700, 2500, 3000, 3300, 3800 Equal with interface 485PB-SMC-NR (S-05-00035), consequently suitable for inverter: SMA SMC 4600A, 5000A, 6000A, SB 1300TL, 1600TL, 2100TL, 7000HV, 9000TL, 10000TL, 11000TL

Price incl. VAT plus delivery

Item number: S-05-00034
Delivery time:
by request

SMA RS485-Interface 485PB-SMC-NR

85.98 €

SMA RS485-Interface, 485PB-SMC-NR, Piggy Back, is used to retrofit

SMA Interface for retrofitting, suitable for inverter: SMA SMC 4600A, 5000A, 6000A, SB 1300TL, 1600TL, 2100TL, 7000HV, 9000TL, 10000TL, 11000TL Eqaul with interface 485PB-NR (S-05-00034), consequently suitable for inverter: SMA SB 1200, 1700, 2500, 3000, 3300, 3800

Price incl. VAT plus delivery

Item number: S-05-00035
Delivery time:
by request

SMA Groundingset "positive" ESHV-P-NR

88.33 €

SMA Grounding-Set, Positiv, ESHV-P-NR, is used to ground the PV generator

If you use special cell technologies in your PV generator (e.g. thin-film PV modules and back-contact PV-modules), it may be necessary to ground the PV generator, either positively or negatively. With this in mind SMA Solar Technology has developed two grounding sets with which the positive or negative grounding of the PV generator, as recommended by the module manufacturer, can be performed already within the inverter. This device-internal grounding provides safe long-term operation and optimum EMC properties while minimizing the installation costs. The grounding set includes a 1 A fuse as protection against the danger of fire and a circuit adjusting the inverter's isolation monitoring to the grounding set. The grounding set directly connects the pole to be grounded (plus or minus) of the PV modules and the inverter's PE connection via the fuse. This circuit has been designed for Germany and is suitable for many other countries as well. Before installation, check if the installation country allows to connect a pole to ground. The positive grounding set (ESHV-P-NR) is used, for example, for certain modules with back-contact cells. The negative grounding set (ESHV-N-NR) is used, for example, for thin-film modules. Your module manufacturer can provide you with information on the necessity and type of grounding of your PV system. Only use the grounding set with the following SMA inverters with transformer: Sunny Boy 1100, Sunny Boy 1200, Sunny Boy 1700, Sunny Boy 2500, Sunny Boy 3000, Sunny Boy 3300, Sunny Boy 3800, Sunny Mini Central 4600A, Sunny Mini Central 5000A, Sunny Mini Central 6000A, Sunny Mini Central 7000HV The inverter may only be operated with PV generators (modules and cabling) constructed with protective insulation (protection class II).

Price incl. VAT plus delivery

Item number: WZ-005
Delivery time:
by request

SMA Groundingset "negative" ESHV-N-NR

94.49 €

SMA Grounding-Set, Negative, ESHV-N-NR, is used to ground the PV generator

If you use special cell technologies in your PV generator (e.g. thin-film PV modules and back-contact PV-modules), it may be necessary to ground the PV generator, either positively or negatively. With this in mind SMA Solar Technology has developed two grounding sets with which the positive or negative grounding of the PV generator, as recommended by the module manufacturer, can be performed already within the inverter. This device-internal grounding provides safe long-term operation and optimum EMC properties while minimizing the installation costs. The grounding set includes a 1 A fuse as protection against the danger of fire and a circuit adjusting the inverter's isolation monitoring to the grounding set. The grounding set directly connects the pole to be grounded (plus or minus) of the PV modules and the inverter's PE connection via the fuse. This circuit has been designed for Germany and is suitable for many other countries as well. Before installation, check if the installation country allows to connect a pole to ground. The positive grounding set (ESHV-P-NR) is used, for example, for certain modules with back-contact cells. The negative grounding set (ESHV-N-NR) is used, for example, for thin-film modules. Your module manufacturer can provide you with information on the necessity and type of grounding of your PV system. Only use the grounding set with the following SMA inverters with transformer: Sunny Boy 1100, Sunny Boy 1200, Sunny Boy 1700, Sunny Boy 2500, Sunny Boy 3000, Sunny Boy 3300, Sunny Boy 3800, Sunny Mini Central 4600A, Sunny Mini Central 5000A, Sunny Mini Central 6000A, Sunny Mini Central 7000HV The inverter may only be operated with PV generators (modules and cabling) constructed with protective insulation (protection class II).

Price incl. VAT plus delivery

Item number: WZ-006
Delivery time:
by request

SMA Bluetooth Interface BTPBINV-NR

99.97 €

SMA Bluetooth Interface, BTPBINV-NR, Piggy Back Bluetooth

SMA Bluetooth Interface for retrofitting, suitable for inverter: SMA SB 1200, SB 1700, SB 2500, SB 3000, SB 3300, SB 3800, SMC 4600A, SMC 5000A, SMC 6000A, SB 1300TL, SB 1600TL, SB 2100TL, SMC 7000HV, SMC 9000TL, SMC 10000TL, SMC 11000TL

Price incl. VAT plus delivery

Item number: S-05-00033
Delivery time:
by request

SMA RS485-Interface 485QM-10-NR

99.97 €

SMA RS485-Interface + Multifunction relay, 485QM-10-NR, Piggy Back

Quick Modul RS485 + Multifunktion-Relais SMA Interface for retrofitting, suitable for inverter: SMA 2000HF-30 / 2500HF-30 / 3000HF-30

Price incl. VAT plus delivery

Item number: S-05-00032
Delivery time:
by request

1 - 10 from 27 Results

© Copyright 2012 NwComp Solar GmbH. All rights reserved.